How many watts does a well pump use?

A well pump uses 655–2,280 watts while running, which is 2.7–9.5 amps at 240 V.

Well pump watts, amps and circuit

Typical power use of a well pump
Running watts655–2,280 W
Voltage240 V
Running amps2.7–9.5 A
Circuitstandard 240 V outlet

Also called: submersible well pump, deep well pump, 1 hp well pump.

Well pump watts by size and type

Running and starting watts of well pump types
Size or typeRunning watts, WVolts, VAmps, AStarting watts, W
Well pump655–2,2802402.7–9.5—
1/2 HP655–9602402.7–4—
3/4 HP925–1,3102403.9–5.5—
1 HP1,160–1,6002404.8–6.7—
1 1/2 HP1,710–2,2802407.1–9.5—
01,0002,0003,000Watts, WSize or typeWell pumpWell pump, Running watts: 655–2,280655–2,2801/2 HP1/2 HP, Running watts: 655–960655–9603/4 HP3/4 HP, Running watts: 925–1,310925–1,3101 HP1 HP, Running watts: 1,160–1,6001,160–1,6001 1/2 HP1 1/2 HP, Running watts: 1,710–2,2801,710–2,28005001,0001,5002,0002,500Watts, WSize or typeWell pumpWell pump, Running watts: 655–2,280655–2,2801/2 HP1/2 HP, Running watts: 655–960655–9603/4 HP3/4 HP, Running watts: 925–1,310925–1,3101 HP1 HP, Running watts: 1,160–1,6001,160–1,6001 1/2 HP1 1/2 HP, Running watts: 1,710–2,2801,710–2,280
Watts of well pump types. The lighter part of a bar is the upper end of the typical range.

What size generator runs a well pump?

A well pump needs a generator that supplies at least 2,280 running watts. Starting a well pump takes a short surge of several times its running watts, and the surge is not listed here: size the generator from the locked-rotor amps (LRA) on the nameplate or the maker's generator guidance, not from the running watts. The generator must have a 240 V outlet or be connected through a transfer switch or interlock.

What it costs to run a well pump

Running a well pump at 1,468 W, the middle of its 655–2,280 W range, for one hour a day uses 535.8 kWh a year. That costs about $96 a year at $0.18 per kWh, the US average residential price for August 2026.

W
h
$/kWh

Your bill's total ÷ kWh used. 0.18 is the US residential average.

Result
$8.04 / month
Per day
$0.26
Per year
$96
Energy per day
1.47 kWh
Energy per month
44.7 kWh

How it is calculated

  1. kWh per day = 1,468 W × 1 h ÷ 1,000 = 1.468
  2. Per month = 1.468 kWh × 30.4 days × $0.18 = $8.04

What affects well pump power use

Motor horsepower sets the running watts: each row runs from full load to the maximum service-factor load of Franklin Electric 4-inch single-phase motors. The pump runs only when the pressure switch calls for water, so the yearly energy use depends on water use and well depth. For a 1 HP motor Franklin lists a minimum generator of 4 kW (3-wire) or 6 kW (2-wire); the breaker comes from the motor nameplate and the control box instructions.

How the amps are calculated

Amps = watts ÷ volts. For 2,280 W at 240 V that is 9.5 A. The 655–2,280 W range covers typical models; the nameplate on a well pump gives the exact figure.