How many watts does a window air conditioner use?
A typical window air conditioner uses 440–1,250 watts when running and draws 3.7–10.4 amps at 120 volts.
Window air conditioner watts, amps and circuit
| Running watts | 440–1,250 W |
|---|---|
| Voltage | 120 V |
| Running amps | 3.7–10.4 A |
| Circuit | standard 120 V outlet |
Also called: window ac, window unit, air conditioner, room air conditioner, small window ac.
Window air conditioner watts by size and type
| Size or type | Running watts, W | Volts, V | Amps, A | Starting watts, W |
|---|---|---|---|---|
| Window air conditioner | 440–1,250 | 120 | 3.7–10.4 | — |
| 5,000 BTU | 440–455 | 120 | 3.7–3.8 | — |
| 6,000 BTU | 495–535 | 120 | 4.1–4.5 | — |
| 8,000 BTU | 660–695 | 120 | 5.5–5.8 | — |
| 10,000 BTU | 865–870 | 120 | 7.2–7.3 | — |
| 12,000 BTU | 1,030–1,060 | 120 | 8.6–8.8 | — |
| 14,000 BTU | 1,250 | 120 | 10.4 | — |
What size generator runs a window air conditioner?
A window air conditioner needs a generator that supplies at least 1,250 running watts. Starting a window air conditioner takes a short surge of several times its running watts, and the surge is not listed here: size the generator from the locked-rotor amps (LRA) on the nameplate or the maker's generator guidance, not from the running watts.
How long a portable power station runs a window air conditioner
| Battery capacity, Wh | At 1,250 W, h | At 440 W, h |
|---|---|---|
| 500 | 0.3 | 1 |
| 1,000 | 0.7 | 1.9 |
| 2,000 | 1.4 | 3.9 |
| 3,600 | 2.4 | 7 |
A 500 Wh portable power station runs a window air conditioner drawing 1,250 W for about 0.3 hours at 85% inverter efficiency. Runtime = capacity × 85% ÷ watts; the 85% efficiency is an assumption. The power station's AC output must be at least 1,250 W.
What it costs to run a window air conditioner
Running a window air conditioner at 845 W, the middle of its 440–1,250 W range, for one hour a day uses 308.4 kWh a year. That costs about $56 a year at $0.18 per kWh, the US average residential price for August 2026.
Your bill's total ÷ kWh used. 0.18 is the US residential average.
- Per day
- $0.15
- Per year
- $56
- Energy per day
- 0.85 kWh
- Energy per month
- 25.7 kWh
How it is calculated
- kWh per day = 845 W × 1 h ÷ 1,000 = 0.845
- Per month = 0.845 kWh × 30.4 days × $0.18 = $4.63
What affects window air conditioner power use
Cooling capacity in BTU and the efficiency rating set the running watts. The rows are the cooling watts GE and Frigidaire list for their 115 V window units. The compressor cycles with the thermostat and needs a short surge to start, which matters on a generator or inverter. The largest window units are made for 240 V outlets; check the plug and nameplate before choosing an outlet.
How the amps are calculated
Amps = watts ÷ volts. For 1,250 W at 120 V that is 10.4 A. The 440–1,250 W range covers typical models; the nameplate on a window air conditioner gives the exact figure.