Septic tank size calculator
The minimum septic tank size is set by each state's rule, by the number of bedrooms. For a 3-bedroom house, 6 of the 9 states compared (North Carolina, New York, Minnesota, Washington, Georgia, Texas) require 1,000 gallons; 3 of the 9 states compared (Virginia, Florida, Pennsylvania) require 900 gallons. Choose your state for its own minimum and its garbage-disposal rule.
In North Carolina a 3-bedroom house needs a septic tank of at least 1,000 gallons under 15A NCAC 18E .0801.
- Minimum by bedrooms
- 1,000 gal
- Same house in the 9 states compared
- 900–1,000 gal
- New York
- 1,000 gal
- Minnesota
- 1,000 gal
- Virginia
- 900 gal
- Washington
- 1,000 gal
- Georgia
- 1,000 gal
- Florida
- 900 gal (worked out)
- Texas
- 1,000 gal (worked out)
- Pennsylvania
- 900 gal (worked out)
How it is calculated
- 15A NCAC 18E .0801: 3 bedrooms → 1,000 gal minimum liquid capacity.
- The rule sets a minimum; a designer or the health department may require more for the soil, the lot or the system type.
How the minimum septic tank size is worked out
The steps use the rules of two of the states compared: one that prints the size by bedrooms and one that gives a flow table.
Step 1: A state that prints the size by bedrooms
Minimum gallons = the row for the number of bedrooms
Example North Carolina, 15A NCAC 18E .0801: 3 bedrooms → 1,000 gallons
Step 2: A state that gives a design flow
Design flow (gallons per day) by bedrooms → tank size from the state table for that flow
Example Florida, Fla. Admin. Code 62-6.008, 4 bedrooms: 400 gpd -> Table II row 301-400 → 1,050 gallons
Florida's flow table also limits the building area for each bedroom count (Table I); a larger house is sized by area, not by bedrooms.
Step 3: Garbage disposal
Minimum + the state adder (a percent of the minimum, or a fixed number of gallons)
Example New York: +250 gal
Example Minnesota: +50%
Example Georgia: +50%
Minimum septic tank size by bedrooms and state
Minimum liquid capacity in gallons by number of bedrooms under each state's rule, without a garbage disposal. A value marked * is worked out from the state's flow table or formula; the calculator shows the working. Texas is shown without water-saving fixtures.
| State and rule | 1 BR | 2 BR | 3 BR | 4 BR | 5 BR | 6 BR |
|---|---|---|---|---|---|---|
| North Carolina 15A NCAC 18E .0801 | 1,000 | 1,000 | 1,000 | 1,000 | 1,250 | — |
| New York 10 NYCRR Appendix 75-A | 1,000 | 1,000 | 1,000 | 1,250 | 1,500 | 1,750 |
| Minnesota Minn. R. 7080.1930 | 1,000 | 1,000 | 1,000 | 1,500 | 1,500 | 2,000 |
| Virginia 12VAC5-610-815 | 750 | 750 | 900 | 1,200 | 1,500 | — |
| Washington WAC 246-272A-0232 | 1,000 | 1,000 | 1,000 | 1,000 | 1,250* | 1,500* |
| Georgia Ga. Comp. R. & Regs. 511-3-1-.05 | 1,000 | 1,000 | 1,000 | 1,000 | 1,250* | 1,500* |
| Florida Fla. Admin. Code 62-6.008 | 900* | 900* | 900* | 1,050* | 1,200* | 1,350* |
| Texas 30 TAC 285.91 | 750* | 750* | 1,000* | 1,250* | 1,250* | 1,313* |
| Pennsylvania 25 Pa. Code 73.17 and 73.31 | 900* | 900* | 900* | 1,250* | 1,400* | 1,550* |
Why the minimum tank size differs between states
States size a septic tank from the number of bedrooms: as the U.S. EPA notes, in most states the design flow is based on the number of bedrooms in the house. Some states print a table of tank sizes by bedrooms; others print the design flow per bedroom and a table or formula that turns the flow into a tank size. Where a state gives only the flow, the calculator works the size out and shows the working.
A rule sets a minimum. The health department or a licensed designer may require a larger tank or two compartments, for example for a garbage disposal, a large house or a pump. Septic systems also need a permit and a soil evaluation before installation.