Pipe volume calculator
Pipe volume in gallons = π × inside diameter² ÷ 4 × length × 12 ÷ 231. 50 ft of 3/4 inch SDR 9 PEX pipe (inside diameter 0.681 in) holds 0.95 gallons, or 3.6 liters. Choose the pipe by material and size; its inside diameter comes from the published dimensions.
0 uses the 0.681 in of 3/4 in SDR 9 PEX pipe
50 ft of 3/4 in SDR 9 PEX pipe holds 0.95 gallons (3.6 L) of water.
- Liters
- 3.58
- Cubic feet
- 0.126
- Gallons per foot
- 0.0189
- Liters per meter
- 0.235
How it is calculated
- bore area = π × 0.681² ÷ 4 = 0.3642 in² (inside diameter = OD − 2 × wall); × 50 ft × 12 in ÷ 231 in³ per gallon = 0.946 gal.
- Liters = gallons × 3.785 = 3.58 L; cubic feet = gallons ÷ 7.48 = 0.126 ft³.
How to calculate the volume of a pipe
The worked numbers use the calculator's default: 50 ft of 3/4 inch SDR 9 PEX pipe.
Step 1: Find the inside diameter
Inside diameter = published ID, or OD − 2 × wall when the document prints no ID
Example 3/4 inch SDR 9 PEX pipe: OD 0.875 in − 2 × wall = 0.681 in
Step 2: Area of the bore
Area (in²) = π × ID² ÷ 4
Example π × 0.681² ÷ 4 = 0.3642 in²
Step 3: Volume in gallons
Gallons = area × length (ft) × 12 ÷ 231
Liters = gallons × 3.785
Example 0.3642 × 50 × 12 ÷ 231 = 0.946 gal
Example 0.946 × 3.785 = 3.58 L
One foot of this pipe holds 0.0189 gallons (0.072 L); for several sizes, add the runs.
How many gallons per foot of pipe?
Gallons and liters per foot and gallons per 100 feet of the pipes used most for home water lines, from the inside diameter of each pipe. Multiply by the length of a run, or use the calculator for a run of mixed sizes.
| Pipe | ID, in | Gallons per foot | Liters per foot | Gallons per 100 ft |
|---|---|---|---|---|
| 1/2″ SDR 9 PEX pipe | 0.485 | 0.0096 | 0.036 | 0.96 |
| 3/4″ SDR 9 PEX pipe | 0.681 | 0.0189 | 0.072 | 1.89 |
| 1″ SDR 9 PEX pipe | 0.875 | 0.0312 | 0.118 | 3.12 |
| 1-1/4″ SDR 9 PEX pipe | 1.069 | 0.0466 | 0.176 | 4.66 |
| 1-1/2″ SDR 9 PEX pipe | 1.263 | 0.0651 | 0.246 | 6.51 |
| 2″ SDR 9 PEX pipe | 1.653 | 0.1115 | 0.422 | 11.15 |
| 1/2″ Type L copper pipe | 0.545 | 0.0121 | 0.046 | 1.21 |
| 3/4″ Type L copper pipe | 0.785 | 0.0251 | 0.095 | 2.51 |
| 1″ Type L copper pipe | 1.025 | 0.0429 | 0.162 | 4.29 |
| 1-1/4″ Type L copper pipe | 1.265 | 0.0653 | 0.247 | 6.53 |
| 1-1/2″ Type L copper pipe | 1.505 | 0.0924 | 0.35 | 9.24 |
| 2″ Type L copper pipe | 1.985 | 0.1608 | 0.609 | 16.08 |
| 1/2″ Schedule 40 PVC pipe | 0.602 | 0.0148 | 0.056 | 1.48 |
| 3/4″ Schedule 40 PVC pipe | 0.804 | 0.0264 | 0.1 | 2.64 |
| 1″ Schedule 40 PVC pipe | 1.029 | 0.0432 | 0.164 | 4.32 |
| 1-1/4″ Schedule 40 PVC pipe | 1.360 | 0.0755 | 0.286 | 7.55 |
| 1-1/2″ Schedule 40 PVC pipe | 1.590 | 0.1031 | 0.39 | 10.31 |
| 2″ Schedule 40 PVC pipe | 2.047 | 0.171 | 0.647 | 17.1 |
| 1/2″ Schedule 40 steel pipe | 0.622 | 0.0158 | 0.06 | 1.58 |
| 3/4″ Schedule 40 steel pipe | 0.824 | 0.0277 | 0.105 | 2.77 |
| 1″ Schedule 40 steel pipe | 1.049 | 0.0449 | 0.17 | 4.49 |
| 1-1/4″ Schedule 40 steel pipe | 1.380 | 0.0777 | 0.294 | 7.77 |
| 1-1/2″ Schedule 40 steel pipe | 1.610 | 0.1058 | 0.4 | 10.58 |
| 2″ Schedule 40 steel pipe | 2.067 | 0.1743 | 0.66 | 17.43 |
Why the inside diameter, not the nominal size
The nominal size of a pipe is a name, not a measurement. Water fills the bore, so the volume depends on the inside diameter, which changes with the material and the wall: Schedule 80 holds less than Schedule 40 of the same nominal size, and copper Type K less than Type M.
The calculator takes the inside diameter of the pipe you choose from the same published dimensions as the pipe size charts. Where a document prints no inside diameter, it is the outside diameter minus twice the wall, and the steps say so.