3/4 inch copper pipe dimensions
3/4 inch Type L copper pipe has an outside diameter of 0.875 in (22.2 mm) and a 0.785 in (19.9 mm) inside diameter. Type K has a 0.065 in wall and a 0.745 in inside diameter; Type M has a 0.032 in wall and a 0.811 in inside diameter. Copper tube uses copper tube sizes (CTS): Types K, L and M of one nominal size share the outside diameter and differ in wall thickness.
3/4 inch copper pipe dimensions by type
| Type | OD, in | OD, mm | Wall, in | ID, in | ID, mm | Gallons per foot | Weight, lb/ft |
|---|---|---|---|---|---|---|---|
| Type K | 0.875 | 22.2 | 0.065 | 0.745 | 18.9 | 0.0226 | 0.641 |
| Type L | 0.875 | 22.2 | 0.045 | 0.785 | 19.9 | 0.0251 | 0.455 |
| Type M | 0.875 | 22.2 | 0.032 | 0.811 | 20.6 | 0.0268 | 0.328 |
How much water does 3/4 inch copper pipe hold?
One foot of 3/4 inch Type L copper pipe holds 0.0251 gallons (0.095 L) of water; 100 feet holds 2.51 gallons.
| Length | Type K, gal | Type L, gal | Type M, gal |
|---|---|---|---|
| 1 ft | 0.0226 | 0.0251 | 0.0268 |
| 10 ft | 0.23 | 0.25 | 0.27 |
| 25 ft | 0.57 | 0.63 | 0.67 |
| 50 ft | 1.13 | 1.26 | 1.34 |
| 100 ft | 2.26 | 2.51 | 2.68 |
For a run of mixed sizes, use the pipe volume calculator.
Is 3/4 inch copper pipe the same size as other 3/4″ pipe?
3/4 inch copper pipe has the same 0.875 in outside diameter as 3/4″ PEX pipe. Pipe of another size system with the same nominal size has a different outside diameter, so its fittings do not fit without an adapter.
| Pipe | OD, in | OD, mm |
|---|---|---|
| copper pipe (this page) | 0.875 | 22.2 |
| PEX pipe | 0.875 | 22.2 |
| PVC pipe | 1.050 | 26.7 |
| steel pipe | 1.050 | 26.7 |
3/4 inch copper pipe compared with the sizes next to it
The next size up, 1 inch, is 0.250 in larger outside and holds 70% more water per foot at Type L.
| Nominal size | OD, in | ID, in | Gallons per foot |
|---|---|---|---|
| 5/8″ | 0.750 | 0.666 | 0.0181 |
| 3/4″ (this page) | 0.875 | 0.785 | 0.0251 |
| 1″ | 1.125 | 1.025 | 0.0429 |
How to tell 3/4 inch copper pipe from other sizes
Measure the outside of the pipe, not the inside: the nominal size is a name, and the inside diameter changes with the type. Read the outside diameter with calipers, or wrap a tape or a strip of paper around the pipe and divide the length by 3.1416. A reading close to 0.875 in (22.2 mm) is 3/4 inch copper pipe or PEX pipe of the same nominal size; the print on the pipe gives the type. The pipe size identifier matches a measurement against every size and material.