Pipe velocity calculator

Velocity in feet per second = gpm × 231 ÷ 60 ÷ (π × ID² ÷ 4) ÷ 12, about 0.4085 × gpm ÷ ID² with the inside diameter in inches. 5 gpm through 3/4 inch SDR 9 PEX pipe (inside diameter 0.681 in) moves at 4.4 ft/s, within the 10 ft/s Uponor North America gives for water service and domestic cold water.

What to find
Pipe material
Nominal size
gpm
Water
Result
4.4 ft/s

5 gpm through 3/4 in SDR 9 PEX pipe moves at 4.4 ft/s, within the 10 ft/s Uponor North America gives for water service and domestic cold water.

Velocity, m/s
1.34
Published limit
10 ft/s
Share of the limit
44%
Flow at the limit
11.4 gpm
Inside diameter
0.681 in
END VIEW, TO SCALEOD 0.875 inID 0.681 in17.3 mmwall 0.0973/4 in SDR 9 PEX pipe

How it is calculated

  1. Bore area = π × 0.681² ÷ 4 = 0.3642 in² (inside diameter = OD − 2 × wall).
  2. Velocity = 5 gpm × 231 in³ ÷ 60 s ÷ 0.3642 in² ÷ 12 = 4.404 ft/s.
  3. Limit: 10 ft/s for water service and domestic cold water (Uponor North America).

How to calculate water velocity in a pipe

The worked numbers use the calculator's default: 5 gpm through 3/4 inch SDR 9 PEX pipe.

Step 1: Area of the bore

Area (in²) = π × ID² ÷ 4

Example π × 0.681² ÷ 4 = 0.3642 in²

Step 2: Flow in cubic inches per second

in³/s = gpm × 231 ÷ 60

Example 5 × 231 ÷ 60 = 19.25 in³/s

Step 3: Velocity

Velocity (ft/s) = in³/s ÷ area ÷ 12

Example 19.25 ÷ 0.3642 ÷ 12 = 4.404 ft/s

The published limit for water service and domestic cold water is 10 ft/s (Uponor North America); this pipe reaches it at 11.4 gpm.

Maximum flow of common pipe sizes at the published velocity limit

The flow in gallons per minute at which each pipe reaches the velocity limit its maker or trade association publishes for cold and for hot water. Steel pipe is left out: the documents checked give no velocity limit for it. A dash means the document gives no limit for that water.

Flow in gpm at the published cold-water and hot-water velocity limits, by pipe, from the inside diameter of each pipe
PipeID, inCold limit, ft/sCold, gpmHot limit, ft/sHot, gpmLimits from
1/2″ SDR 9 PEX pipe0.485105.884.6Uponor North America
3/4″ SDR 9 PEX pipe0.6811011.489.1Uponor North America
1″ SDR 9 PEX pipe0.8751018.7815Uponor North America
1-1/4″ SDR 9 PEX pipe1.0691028822.4Uponor North America
1-1/2″ SDR 9 PEX pipe1.2631039831.2Uponor North America
2″ SDR 9 PEX pipe1.6531066.9853.5Uponor North America
1/2″ Type L copper pipe0.54585.853.6Copper Development Association
3/4″ Type L copper pipe0.785812.157.5Copper Development Association
1″ Type L copper pipe1.025820.6512.9Copper Development Association
1-1/4″ Type L copper pipe1.265831.3519.6Copper Development Association
1-1/2″ Type L copper pipe1.505844.4527.7Copper Development Association
2″ Type L copper pipe1.985877.2548.2Copper Development Association
1/2″ Schedule 40 PVC pipe0.60254.4——Charlotte Pipe and Foundry Co.
3/4″ Schedule 40 PVC pipe0.80457.9——Charlotte Pipe and Foundry Co.
1″ Schedule 40 PVC pipe1.029513——Charlotte Pipe and Foundry Co.
1-1/4″ Schedule 40 PVC pipe1.360522.6——Charlotte Pipe and Foundry Co.
1-1/2″ Schedule 40 PVC pipe1.590530.9——Charlotte Pipe and Foundry Co.
2″ Schedule 40 PVC pipe2.047551.3——Charlotte Pipe and Foundry Co.

Why pipe makers limit water velocity

Fast water is noisy, wears the inside of the pipe and makes a stronger pressure surge (water hammer) when a valve closes quickly. Pipe makers and trade associations therefore publish a maximum velocity: for copper tube, 8 ft/s for cold water and 5 ft/s for hot water up to approximately 140°F (Copper Development Association); the calculator compares the result with the published limit for the material you choose.

Hot water gets a lower limit than cold in copper and PEX; the PVC limit is for cold water. The documents checked give no limit for steel pipe, so for steel the calculator gives the velocity without a comparison.