2 inch copper pipe dimensions

2 inch Type L copper pipe has an outside diameter of 2.125 in (54.0 mm) and a 1.985 in (50.4 mm) inside diameter. Type K has a 0.083 in wall and a 1.959 in inside diameter; Type M has a 0.058 in wall and a 2.009 in inside diameter; DWV has a 0.042 in wall and a 2.041 in inside diameter. Copper tube uses copper tube sizes (CTS): Types K, L and M of one nominal size share the outside diameter and differ in wall thickness.

2 inch copper pipe dimensions by type

2 inch copper pipe: outside diameter, wall and inside diameter in inches and millimeters as published in the documents below
TypeOD, inOD, mmWall, inID, inID, mmGallons per footWeight, lb/ft
Type K2.12554.00.0831.95949.80.15662.060
Type L2.12554.00.0701.98550.40.16081.750
Type M2.12554.00.0582.00951.00.16471.460
DWV2.12554.00.0422.04151.80.171.070
END VIEW, TO SCALEOD 2.125 inID 1.985 in50.4 mmwall 0.0702 in Type L copper pipe

How much water does 2 inch copper pipe hold?

One foot of 2 inch Type L copper pipe holds 0.1608 gallons (0.609 L) of water; 100 feet holds 16.08 gallons.

Water held by 2 inch copper pipe by length, from the inside diameter of each type
LengthType K, galType L, galType M, galDWV, gal
1 ft0.15660.16080.16470.17
10 ft1.571.611.651.7
25 ft3.914.024.124.25
50 ft7.838.048.238.5
100 ft15.6616.0816.4717

For a run of mixed sizes, use the pipe volume calculator.

Is 2 inch copper pipe the same size as other 2″ pipe?

2 inch copper pipe has the same 2.125 in outside diameter as 2″ PEX pipe. Pipe of another size system with the same nominal size has a different outside diameter, so its fittings do not fit without an adapter.

Outside diameter of 2″ pipe by material
PipeOD, inOD, mm
copper pipe (this page)2.12554.0
PEX pipe2.12554.0
PVC pipe2.37560.3
steel pipe2.37560.3

2 inch copper pipe compared with the sizes next to it

The next size up, 2-1/2 inch, is 0.500 in larger outside and holds 54% more water per foot at Type L.

Copper pipe one size down, this size and one size up at Type L: outside and inside diameter in inches and gallons per foot
Nominal sizeOD, inID, inGallons per foot
1-1/2″1.6251.5050.0924
2″ (this page)2.1251.9850.1608
2-1/2″2.6252.4650.2479

How to tell 2 inch copper pipe from other sizes

Measure the outside of the pipe, not the inside: the nominal size is a name, and the inside diameter changes with the type. Read the outside diameter with calipers, or wrap a tape or a strip of paper around the pipe and divide the length by 3.1416. A reading close to 2.125 in (54.0 mm) is 2 inch copper pipe or PEX pipe of the same nominal size; the print on the pipe gives the type. The pipe size identifier matches a measurement against every size and material.