2 inch steel pipe dimensions

2 inch Schedule 40 steel pipe has an outside diameter of 2.375 in (60.3 mm) and a 2.067 in (52.5 mm) inside diameter. Schedule 80 has a 0.218 in wall and a 1.939 in inside diameter. Steel pipe uses iron pipe sizes (IPS): each nominal size has one outside diameter, and the wall grows with the schedule.

2 inch steel pipe dimensions by schedule

2 inch steel pipe: outside diameter, wall and inside diameter in inches and millimeters as published in the documents below
VariantOD, inOD, mmWall, inID, inID, mmGallons per footWeight, lb/ft
Schedule 402.37560.30.1542.06752.50.17433.660
Schedule 802.37560.30.2181.93949.30.15345.030
END VIEW, TO SCALEOD 2.375 inID 2.067 in52.5 mmwall 0.1542 in Schedule 40 steel pipe

How much water does 2 inch steel pipe hold?

One foot of 2 inch Schedule 40 steel pipe holds 0.1743 gallons (0.660 L) of water; 100 feet holds 17.43 gallons.

Water held by 2 inch steel pipe by length, from the inside diameter of each variant
LengthSchedule 40, galSchedule 80, gal
1 ft0.17430.1534
10 ft1.741.53
25 ft4.363.83
50 ft8.727.67
100 ft17.4315.34

For a run of mixed sizes, use the pipe volume calculator.

Is 2 inch steel pipe the same size as other 2″ pipe?

2 inch steel pipe has the same 2.375 in outside diameter as 2″ PVC pipe. Pipe of another size system with the same nominal size has a different outside diameter, so its fittings do not fit without an adapter.

Outside diameter of 2″ pipe by material
PipeOD, inOD, mm
steel pipe (this page)2.37560.3
copper pipe2.12554.0
PEX pipe2.12554.0
PVC pipe2.37560.3

2 inch steel pipe compared with the sizes next to it

The next size up, 2-1/2 inch, is 0.500 in larger outside and holds 43% more water per foot at Schedule 40.

Steel pipe one size down, this size and one size up at Schedule 40: outside and inside diameter in inches and gallons per foot
Nominal sizeOD, inID, inGallons per foot
1-1/2″1.9001.6100.1058
2″ (this page)2.3752.0670.1743
2-1/2″2.8752.4690.2487

How to tell 2 inch steel pipe from other sizes

Measure the outside of the pipe, not the inside: the nominal size is a name, and the inside diameter changes with the wall. Read the outside diameter with calipers, or wrap a tape or a strip of paper around the pipe and divide the length by 3.1416. A reading close to 2.375 in (60.3 mm) is 2 inch steel pipe or PVC pipe of the same nominal size; the print on the pipe gives the schedule. The pipe size identifier matches a measurement against every size and material.