3/4 inch PVC pipe dimensions
3/4 inch Schedule 40 PVC pipe has an outside diameter of 1.050 in (26.7 mm) and a 0.804 in (20.4 mm) average inside diameter. Schedule 80 has a 0.154 in wall and a 0.722 in inside diameter. PVC pipe uses iron pipe sizes (IPS): each nominal size has one outside diameter, and the wall grows with the schedule.
3/4 inch PVC pipe dimensions by schedule
| Variant | OD, in | OD, mm | Min. wall, in | ID, in | ID, mm | Gallons per foot | Weight, lb/ft | Max pressure, psi |
|---|---|---|---|---|---|---|---|---|
| Schedule 40 | 1.050 | 26.7 | 0.113 | 0.804 average | 20.4 | 0.0264 | 0.226 | 480 |
| Schedule 80 | 1.050 | 26.7 | 0.154 | 0.722 average | 18.3 | 0.0213 | 0.314 | 690 |
Maximum working pressure as the document gives it: water, non-shock, at 73°F.
How much water does 3/4 inch PVC pipe hold?
One foot of 3/4 inch Schedule 40 PVC pipe holds 0.0264 gallons (0.100 L) of water; 100 feet holds 2.64 gallons.
| Length | Schedule 40, gal | Schedule 80, gal |
|---|---|---|
| 1 ft | 0.0264 | 0.0213 |
| 10 ft | 0.26 | 0.21 |
| 25 ft | 0.66 | 0.53 |
| 50 ft | 1.32 | 1.06 |
| 100 ft | 2.64 | 2.13 |
For a run of mixed sizes, use the pipe volume calculator.
Is 3/4 inch PVC pipe the same size as other 3/4″ pipe?
3/4 inch PVC pipe has the same 1.050 in outside diameter as 3/4″ steel pipe. Pipe of another size system with the same nominal size has a different outside diameter, so its fittings do not fit without an adapter.
| Pipe | OD, in | OD, mm |
|---|---|---|
| PVC pipe (this page) | 1.050 | 26.7 |
| copper pipe | 0.875 | 22.2 |
| PEX pipe | 0.875 | 22.2 |
| steel pipe | 1.050 | 26.7 |
3/4 inch PVC pipe compared with the sizes next to it
The next size up, 1 inch, is 0.265 in larger outside and holds 64% more water per foot at Schedule 40.
| Nominal size | OD, in | ID, in | Gallons per foot |
|---|---|---|---|
| 1/2″ | 0.840 | 0.602 | 0.0148 |
| 3/4″ (this page) | 1.050 | 0.804 | 0.0264 |
| 1″ | 1.315 | 1.029 | 0.0432 |
How to tell 3/4 inch PVC pipe from other sizes
Measure the outside of the pipe, not the inside: the nominal size is a name, and the inside diameter changes with the wall. Read the outside diameter with calipers, or wrap a tape or a strip of paper around the pipe and divide the length by 3.1416. A reading close to 1.050 in (26.7 mm) is 3/4 inch PVC pipe or steel pipe of the same nominal size; the print on the pipe gives the schedule. The pipe size identifier matches a measurement against every size and material.