Schedule 40 vs Schedule 80 PVC pipe

Schedule 40 and Schedule 80 PVC pipe of one nominal size have the same outside diameter; Schedule 80 has the thicker wall. 1/2 inch Schedule 40 has a 0.109 in wall and a 0.602 in inside diameter, Schedule 80 a 0.147 in wall and a 0.526 in inside diameter; they are rated 600 and 850 psi (water, non-shock, at 73°F). The smaller bore holds 24% less water per foot.

Schedule 40 vs Schedule 80 PVC pipe by size

Outside diameter, wall and inside diameter of Schedule 40 and Schedule 80 PVC pipe in inches as published (minimum wall, average inside diameter), with gallons per foot and maximum working pressure (water, non-shock, at 73°F)
Nominal sizeOD, inSchedule 40 wallSchedule 80 wallSchedule 40 IDSchedule 80 IDSchedule 40 gal/ftSchedule 80 gal/ftSchedule 40 psiSchedule 80 psi
1/4″0.5400.0880.1190.3440.2820.00480.00327801,130
3/8″0.6750.0910.1260.4730.4030.00910.0066620920
1/2″0.8400.1090.1470.6020.5260.01480.0113600850
3/4″1.0500.1130.1540.8040.7220.02640.0213480690
1″1.3150.1330.1791.0290.9360.04320.0357450630
1-1/4″1.6600.1400.1911.3601.2550.07550.0643370520
1-1/2″1.9000.1450.2001.5901.4760.10310.0889330470
2″2.3750.1540.2182.0471.9130.1710.1493280400
2-1/2″2.8750.2030.2762.4452.2900.24390.214300420
3″3.5000.2160.3003.0422.8640.37760.3347260370
3-1/2″4.0000.2260.3183.5213.3260.50580.4513240350
4″4.5000.2370.3373.9983.7860.65210.5848220320
5″5.5630.2580.3755.0164.7681.02650.9275190290
6″6.6250.2800.4326.0315.7091.4841.3298180280
8″8.6250.3220.5007.9427.5652.57352.3349160250
10″10.7500.3650.5939.9769.4934.06043.6768140230
12″12.7500.4060.68711.88911.2945.7675.2042130230

How the difference between Schedule 40 and Schedule 80 is worked out

The inside diameters are the ones the document prints (an average, so they are a little smaller than OD − 2 × minimum wall); only where a document prints none is the inside diameter OD − 2 × wall. The water a foot of pipe holds is π × ID² ÷ 4 × 12 ÷ 231 gallons: for 1/2 inch, 0.0148 gallons in Schedule 40 and 0.0113 in Schedule 80.

Which schedule to choose

Both schedules of one nominal size fit the same fittings, because the outside diameter is the same; only the wall differs. The thicker wall of Schedule 80 gives it a higher published pressure rating and a smaller bore, so a run of Schedule 80 carries a little less water than the same run of Schedule 40.

Which schedule a job needs is set by the local plumbing code, the pressure and temperature of the system and the manufacturer’s instructions. Check the print on the pipe: it names the schedule and the standard it is made to.