1/2 inch PVC pipe dimensions
1/2 inch Schedule 40 PVC pipe has an outside diameter of 0.840 in (21.3 mm) and a 0.602 in (15.3 mm) average inside diameter. Schedule 80 has a 0.147 in wall and a 0.526 in inside diameter. PVC pipe uses iron pipe sizes (IPS): each nominal size has one outside diameter, and the wall grows with the schedule.
1/2 inch PVC pipe dimensions by schedule
| Variant | OD, in | OD, mm | Min. wall, in | ID, in | ID, mm | Gallons per foot | Weight, lb/ft | Max pressure, psi |
|---|---|---|---|---|---|---|---|---|
| Schedule 40 | 0.840 | 21.3 | 0.109 | 0.602 average | 15.3 | 0.0148 | 0.170 | 600 |
| Schedule 80 | 0.840 | 21.3 | 0.147 | 0.526 average | 13.4 | 0.0113 | 0.231 | 850 |
Maximum working pressure as the document gives it: water, non-shock, at 73°F.
How much water does 1/2 inch PVC pipe hold?
One foot of 1/2 inch Schedule 40 PVC pipe holds 0.0148 gallons (0.056 L) of water; 100 feet holds 1.48 gallons.
| Length | Schedule 40, gal | Schedule 80, gal |
|---|---|---|
| 1 ft | 0.0148 | 0.0113 |
| 10 ft | 0.15 | 0.11 |
| 25 ft | 0.37 | 0.28 |
| 50 ft | 0.74 | 0.56 |
| 100 ft | 1.48 | 1.13 |
For a run of mixed sizes, use the pipe volume calculator.
Is 1/2 inch PVC pipe the same size as other 1/2″ pipe?
1/2 inch PVC pipe has the same 0.840 in outside diameter as 1/2″ steel pipe. Pipe of another size system with the same nominal size has a different outside diameter, so its fittings do not fit without an adapter.
| Pipe | OD, in | OD, mm |
|---|---|---|
| PVC pipe (this page) | 0.840 | 21.3 |
| copper pipe | 0.625 | 15.9 |
| PEX pipe | 0.625 | 15.9 |
| steel pipe | 0.840 | 21.3 |
1/2 inch PVC pipe compared with the sizes next to it
The next size up, 3/4 inch, is 0.210 in larger outside and holds 78% more water per foot at Schedule 40.
| Nominal size | OD, in | ID, in | Gallons per foot |
|---|---|---|---|
| 3/8″ | 0.675 | 0.473 | 0.0091 |
| 1/2″ (this page) | 0.840 | 0.602 | 0.0148 |
| 3/4″ | 1.050 | 0.804 | 0.0264 |
How to tell 1/2 inch PVC pipe from other sizes
Measure the outside of the pipe, not the inside: the nominal size is a name, and the inside diameter changes with the wall. Read the outside diameter with calipers, or wrap a tape or a strip of paper around the pipe and divide the length by 3.1416. A reading close to 0.840 in (21.3 mm) is 1/2 inch PVC pipe or steel pipe of the same nominal size; the print on the pipe gives the schedule. The pipe size identifier matches a measurement against every size and material.