3/4 inch steel pipe dimensions

3/4 inch Schedule 40 steel pipe has an outside diameter of 1.050 in (26.7 mm) and a 0.824 in (20.9 mm) inside diameter. Schedule 80 has a 0.154 in wall and a 0.742 in inside diameter. Steel pipe uses iron pipe sizes (IPS): each nominal size has one outside diameter, and the wall grows with the schedule.

3/4 inch steel pipe dimensions by schedule

3/4 inch steel pipe: outside diameter, wall and inside diameter in inches and millimeters as published in the documents below
VariantOD, inOD, mmWall, inID, inID, mmGallons per footWeight, lb/ft
Schedule 401.05026.70.1130.82420.90.02771.130
Schedule 801.05026.70.1540.74218.80.02251.480
END VIEW, TO SCALEOD 1.050 inID 0.824 in20.9 mmwall 0.1133/4 in Schedule 40 steel pipe

How much water does 3/4 inch steel pipe hold?

One foot of 3/4 inch Schedule 40 steel pipe holds 0.0277 gallons (0.105 L) of water; 100 feet holds 2.77 gallons.

Water held by 3/4 inch steel pipe by length, from the inside diameter of each variant
LengthSchedule 40, galSchedule 80, gal
1 ft0.02770.0225
10 ft0.280.22
25 ft0.690.56
50 ft1.391.12
100 ft2.772.25

For a run of mixed sizes, use the pipe volume calculator.

Is 3/4 inch steel pipe the same size as other 3/4″ pipe?

3/4 inch steel pipe has the same 1.050 in outside diameter as 3/4″ PVC pipe. Pipe of another size system with the same nominal size has a different outside diameter, so its fittings do not fit without an adapter.

Outside diameter of 3/4″ pipe by material
PipeOD, inOD, mm
steel pipe (this page)1.05026.7
copper pipe0.87522.2
PEX pipe0.87522.2
PVC pipe1.05026.7

3/4 inch steel pipe compared with the sizes next to it

The next size up, 1 inch, is 0.265 in larger outside and holds 62% more water per foot at Schedule 40.

Steel pipe one size down, this size and one size up at Schedule 40: outside and inside diameter in inches and gallons per foot
Nominal sizeOD, inID, inGallons per foot
1/2″0.8400.6220.0158
3/4″ (this page)1.0500.8240.0277
1″1.3151.0490.0449

How to tell 3/4 inch steel pipe from other sizes

Measure the outside of the pipe, not the inside: the nominal size is a name, and the inside diameter changes with the wall. Read the outside diameter with calipers, or wrap a tape or a strip of paper around the pipe and divide the length by 3.1416. A reading close to 1.050 in (26.7 mm) is 3/4 inch steel pipe or PVC pipe of the same nominal size; the print on the pipe gives the schedule. The pipe size identifier matches a measurement against every size and material.