Copper pipe Type L vs Type M

Type L and Type M copper pipe of one nominal size have the same outside diameter; Type L has the thicker wall. 3/4 inch Type L has a 0.045 in wall and a 0.785 in inside diameter, Type M a 0.032 in wall and a 0.811 in inside diameter. The smaller bore holds 6% less water per foot.

Type L vs Type M copper pipe by size

Outside diameter, wall and inside diameter of Type L and Type M copper pipe in inches as published, with gallons per foot
Nominal sizeOD, inType L wallType M wallType L IDType M IDType L gal/ftType M gal/ft
3/8″0.5000.0350.0250.4300.4500.00750.0083
1/2″0.6250.0400.0280.5450.5690.01210.0132
3/4″0.8750.0450.0320.7850.8110.02510.0268
1″1.1250.0500.0351.0251.0550.04290.0454
1-1/4″1.3750.0550.0421.2651.2910.06530.068
1-1/2″1.6250.0600.0491.5051.5270.09240.0951
2″2.1250.0700.0581.9852.0090.16080.1647
2-1/2″2.6250.0800.0652.4652.4950.24790.254
3″3.1250.0900.0722.9452.9810.35390.3626
3-1/2″3.6250.1000.0833.4253.4590.47860.4882
4″4.1250.1100.0953.9053.9350.62220.6318

How the difference between Type L and Type M is worked out

The inside diameters are the ones the document prints; only where a document prints none is the inside diameter OD − 2 × wall. The water a foot of pipe holds is π × ID² ÷ 4 × 12 ÷ 231 gallons: for 3/4 inch, 0.0251 gallons in Type L and 0.0268 in Type M.

How to tell Type L from Type M

Copper water tube of one nominal size has the same outside diameter in Types K, L and M, so the same fittings fit all three; the types differ in wall thickness. Type K has the thickest wall, Type L is in between, and Type M has the thinnest. A thinner wall means a slightly larger bore and a lighter tube.

Copper water tube is marked with its type, and the copper industry color-codes the markings by type. Which type a job needs is set by the local plumbing code and the use (inside the house, buried, or in a slab).