What size drain pipe for a bathroom sink?

A bathroom sink needs at least a 1-1/4 inch trap and drain under both the International Plumbing Code (IPC) and the Uniform Plumbing Code (UPC). It counts as 1 drainage fixture unit under both codes. Your state or city may use either code, with amendments.

Bathroom sink drain size in each document

Trap size and drainage fixture units of the bathroom sink as printed in each document, by code
CodeTrap, inDFUDocument
IPC1-1/41NC Building Code Council / NC Office of Administrative Hearings
UPC1-1/41Minnesota Office of the Revisor of Statutes / Dept. of Labor and Industry
UPC1-1/41Public Health - Seattle & King County, WA

Which code applies where you live

The model codes are adopted state by state. UPC: AK, CA, HI, IA, ID, MN, MT, NM, OR, WA. IPC: CO, FL, GA, IN, LA, MD, MI, NC, NY, OH, PA, TN, UT, VA. Cities and counties can amend them; the local building department has the final word.

Before you plumb the drain

The trap size is the smallest the code allows for this fixture. A drain line that collects several fixtures is sized from the sum of their drainage fixture units, and every drain needs a vent and a minimum slope; see the drain size chart and the drain slope calculator.