CTS vs IPS pipe size

IPS (iron pipe size) and CTS (copper tube size) are two sets of outside diameters for the same nominal sizes. 1/2 inch IPS pipe, such as steel and PVC, is 0.840 in (21.3 mm) outside; 1/2 inch CTS tube, such as copper and PEX, is 0.625 in (15.9 mm). The two are not interchangeable: their fittings differ.

Outside diameter of IPS and CTS pipe by nominal size

Outside diameter in inches of iron pipe size (steel and PVC) and copper tube size (copper and PEX) pipe of the same nominal size, as published
Nominal sizeIPS OD, inCTS OD, inDifference, in
1/4″0.5400.3750.165
3/8″0.6750.5000.175
1/2″0.8400.6250.215
3/4″1.0500.8750.175
1″1.3151.1250.190
1-1/4″1.6601.3750.285
1-1/2″1.9001.6250.275
2″2.3752.1250.250
2-1/2″2.8752.6250.250
3″3.5003.1250.375
3-1/2″4.0003.6250.375
4″4.5004.1250.375

How to tell IPS from CTS

Measure the outside diameter and compare it with the table: 0.840 in is 1/2 inch IPS, 0.625 in is 1/2 inch CTS. Calipers read it directly; a tape around the pipe reads π × the outside diameter.

Why the two size systems matter

A fitting is made for one outside diameter, so a 1/2 inch fitting for PVC or steel pipe does not fit 1/2 inch copper tube or PEX, even though both are called 1/2 inch. Joining the two systems takes a transition fitting made for it.

The print on the pipe usually names the system: IPS on PVC and steel pipe, CTS on copper tube, PEX and CPVC water pipe. When the print is gone, measuring the outside diameter tells the two systems apart.