CTS vs IPS pipe size
IPS (iron pipe size) and CTS (copper tube size) are two sets of outside diameters for the same nominal sizes. 1/2 inch IPS pipe, such as steel and PVC, is 0.840 in (21.3 mm) outside; 1/2 inch CTS tube, such as copper and PEX, is 0.625 in (15.9 mm). The two are not interchangeable: their fittings differ.
Outside diameter of IPS and CTS pipe by nominal size
| Nominal size | IPS OD, in | CTS OD, in | Difference, in |
|---|---|---|---|
| 1/4″ | 0.540 | 0.375 | 0.165 |
| 3/8″ | 0.675 | 0.500 | 0.175 |
| 1/2″ | 0.840 | 0.625 | 0.215 |
| 3/4″ | 1.050 | 0.875 | 0.175 |
| 1″ | 1.315 | 1.125 | 0.190 |
| 1-1/4″ | 1.660 | 1.375 | 0.285 |
| 1-1/2″ | 1.900 | 1.625 | 0.275 |
| 2″ | 2.375 | 2.125 | 0.250 |
| 2-1/2″ | 2.875 | 2.625 | 0.250 |
| 3″ | 3.500 | 3.125 | 0.375 |
| 3-1/2″ | 4.000 | 3.625 | 0.375 |
| 4″ | 4.500 | 4.125 | 0.375 |
How to tell IPS from CTS
Measure the outside diameter and compare it with the table: 0.840 in is 1/2 inch IPS, 0.625 in is 1/2 inch CTS. Calipers read it directly; a tape around the pipe reads π × the outside diameter.
Why the two size systems matter
A fitting is made for one outside diameter, so a 1/2 inch fitting for PVC or steel pipe does not fit 1/2 inch copper tube or PEX, even though both are called 1/2 inch. Joining the two systems takes a transition fitting made for it.
The print on the pipe usually names the system: IPS on PVC and steel pipe, CTS on copper tube, PEX and CPVC water pipe. When the print is gone, measuring the outside diameter tells the two systems apart.